Governing evidence and applicability rules (take precedence over aggregate bands): establish the document purpose, design, stage and available evidence before rating. A fit-for-purpose single-method design can earn the highest applicable rating; do not require complexity, mixed methods or two sources for every finding. Distinguish applicable, not applicable with reason, not evidenced, and observed inadequate. Report applicable coverage and the raw denominator. If any dimension is N/A or not evidenced, report the profile and gaps without a 25-point band or an unvalidated rescaled equivalent. Never interpret missing documentation as proof no activity occurred. Use source-linked historical facts only; keep proposed work and illustrative examples separate. Preserve unresolved source conflicts. Do not invent baseline values, quotations, fieldwork, pilots, validation, consent or approvals to improve a score. A serious consent, confidentiality, safeguarding, measurement-validity or unsupported-inference failure is a blocking issue regardless of the total, including 22/25. High document-quality scores do not establish legal compliance, instrument readiness, field authorization or donor approval. Accountable human review against the applicable protocol is separate. A well-documented failed pilot may score 25/25 for documentation while remaining not ready for fielding.
Use This Rubric
Bring: the indicator statements and definitions, results framework, data-source plans, relevant reporting requirements, and any targets.
Stage: State whether this is a proposed design, a draft, or a report of completed work. Assess planned procedures as plans; require records before claiming they occurred. A complete submitted document can have an observed documentation defect even when the underlying activity is unknown.
Limits: Apply requirements to the stated purpose, methods, population, and risk. Do not impose extra methods or sensitive data collection solely to increase a score. These editorial anchors are provisionally checked, not practitioner-calibrated.
Scoring Criteria
All five SMART elements present. Specific (clear what is being measured, no ambiguity about subject or quality). Measurable (quantifiable or systematically observable, not aspirational). Achievable (realistic given context, capacity, and timeframe). Relevant (matches the result level it claims to measure, e.g., outcome indicators measure outcomes). Time-bound (deadline or measurement schedule specified).
At least four SMART elements present. One element partial or weakly evidenced.
At least three SMART elements present. Notable gaps in specificity, measurability, or time-bounding.
Two or fewer SMART elements present. Indicator is largely aspirational or vague.
No SMART criteria met. Indicator is a slogan or a result statement, not an indicator.
All 4 elements: Unambiguous indicator definition (no room for different interpretations across people or sites). Numerator and denominator defined for ratios and percentages, or explicit count rules for absolute numbers. Unit of analysis named (person, household, community, event, transaction). Calculation method documented (how the value is computed step by step).
Three of four elements adequately specified; the remaining element incomplete: Definition clear and unit named; numerator/denominator or calculation method partial.
Indicator defined at a high level. Unit implied. Numerator/denominator or calculation logic missing.
Definition is the indicator name restated. No calculation logic.
No definition beyond a label.
All 4 elements: Standard disaggregations included (sex and age at minimum, where relevant). Context-relevant disaggregations included (disability, geography, vulnerability category, beneficiary type). Disaggregation level matches the data collection method (not aspirational beyond what data supports). Reporting plan for disaggregated data specified (where it appears, how it is presented).
Three of four elements adequately specified; the remaining element incomplete: Standard and one context disaggregation included; reporting plan or feasibility partial.
Sex disaggregation only. No context disaggregation. Feasibility against data collection unexamined.
Disaggregation listed without specifying categories or reporting plan.
No disaggregation specified.
All 4 elements: Specific data source named (not generic "monitoring data", e.g., "service delivery records from clinic registers"). Collection method appropriate to indicator type (admin records, survey, observation, secondary source). Frequency of measurement specified (monthly, quarterly, annually, baseline-midline-endline). Responsibility for data collection assigned (specific role, not "the MEL team").
Three of four elements adequately specified; the remaining element incomplete: Source named and method appropriate; frequency or responsibility partial.
Source generic ("project data"). Method named but not justified for the indicator. Frequency vague.
Source unspecified. Method unspecified or mismatched.
No data source, method, frequency, or responsibility documented.
All 4 elements: Indicator at right result-chain level (input, output, outcome, impact appropriately tagged). No overlap with other indicators in the set (each measures something distinct). Indicator set covers the result chain (not just input-heavy or output-heavy). Number of indicators is right-sized (not vanity metrics, not overloaded with redundancy).
Three of four elements adequately specified; the remaining element incomplete: Levels mostly correct and set covers the chain; minor overlap or one off-level indicator.
Result-chain level inconsistently applied. Some overlap. Coverage skewed toward one level.
Levels mislabeled or mixed. Significant redundancy. Coverage gaps at outcome or impact level.
No level tagging. Indicators are duplicative or disconnected from the result chain.
Score Interpretation
Report blockers, the dimension profile, and evidence coverage first. Use these aggregate bands only when all five dimensions are applicable and sufficiently evidenced with no unresolved evidence conflict. Otherwise give no total, band, or rescaled equivalent. High documentation quality does not establish readiness, legal compliance, or approval.
| Total (out of 25) | Band | Next Step |
|---|---|---|
| 22-25 | Strong | Strong documentation profile only. Resolve blocking issues and obtain the applicable human review; this score does not authorize use. |
| 17-21 | Adequate | Prioritize source-linked revisions in the weakest dimensions. Request missing records before proposing additional activity; confirm the need for any new work from evidence. |
| 11-16 | Needs Revision | Use located findings as a revision brief. Distinguish reporting gaps from demonstrated design or implementation failures and label proposed work for confirmation. |
| 5-10 | Substantial Revision | Rework the evidence-backed weaknesses with accountable review. A low documentation profile alone does not establish that the underlying activity failed or must be repeated. |